Continuation - Fire Damaged Heirloom - Chassis

The chassis has been recapped, tubes tested, panel lights replaced, all resistors tested and several replaced. The treble potentiometer was replaced with the one from the parts set because the original played with too much static. I also replaced the power cord because the original was repaired using electrical tape. The set sounds great on the bench.




I also replaced the EM84 "magic eye" tube. It responds to station changes and shines brightly.



Components that were replaced


Now for the reassembly into the new case.